Messages in this thread | | | Date | Sun, 12 Dec 2010 13:53:06 +0000 | From | Mark Brown <> | Subject | Re: [PATCH] regulator: Call into regulator driver only when voltage min/max really changes. |
| |
On Sun, Dec 12, 2010 at 02:55:40AM -0800, Saravana Kannan wrote: > Even in cases where the consumer driver calls the regulator core with > different voltage min/max values, the application of the various > voltage constraints could result in the min/max voltage values passed > to the regulator driver to be unchanged since the previous invocation.
So, I tried to apply this against my local tree to avoid collisions with it but it doesn't apply so I suspect Liam will have trouble also, there are several updates in there that overlap with your change. Please regenerate against -next or Liam's tree:
git://git.kernel.org/pub/scm/linux/kernel/git/lrg/voltage-2.6
You should always submit changes against the development versions of code, generally -next will have these merged into it.
| |