Messages in this thread | | | Subject | Re: [PATCH 1/3] regulator: Use _regulator_get_voltage() consistently | From | Liam Girdwood <> | Date | Fri, 10 Dec 2010 22:13:47 +0000 |
| |
On Fri, 2010-12-10 at 17:28 +0000, Mark Brown wrote: > Rather than referencing the get_voltage() operation directly in the > ops struct use the internal _regulator_get_voltage() API call to do > so, facilitating refactoring. > > Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All Applied.
Thanks