[lkml]   [2010]   [Oct]   [25]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
Messages in this thread
    SubjectRe: [PATCH] ACPI / Battery: Return -ENODATA for unknown values in get_property()
    On Monday, October 25, 2010, Pavel Machek wrote:
    > Hi!
    > > That's why I suggested to use -ENODATA. :-)
    > >
    > > Still, if user space has problems with failing reads from the sysfs attributes,
    > > it may be better to simply put -1 in there. Patch is appended, please test.
    > I'd say that reporting -1 for unknown is ugly. You can have -1A
    > current easily (charging at 1A), and I've seen machines reporting <0
    > current -- when charging. Logical and well-defined.

    I posted a patch fixing that in a different way (makng the battery driver return
    -ENODEV instead of -ENODATA) in the meantime, which has been confirmed to work.


     \ /
      Last update: 2010-10-25 22:39    [W:0.041 / U:20.752 seconds]