Messages in this thread | | | Date | Thu, 3 Dec 2009 00:31:56 +0200 | From | Felipe Balbi <> | Subject | Re: [PATCH] power_supply: Add driver for TWL4030/TPS65950 BCI charger |
| |
Hi,
On Wed, Dec 02, 2009 at 10:54:42PM +0100, ext Anton Vorontsov wrote: >As for the default USB VBUS current value, it could be Kconfig >option (something alike to USB_GADGET_VBUS_DRAW) and/or module >parameter, or hw default, or hardcoded for now. Either will >work.
cannot be Kconfig, it's mandated by usb battery charging spec 1.x to be 100mA for 100ms, then if you don't enumerate, you have to cut charging.
> >-- >Anton Vorontsov >email: cbouatmailru@gmail.com >irc://irc.freenode.net/bd2
-- balbi
| |