    SubjectRe: Doubt about Regulator Framework and VBAT use case
    ext Mark Brown <> writes:

    > On Wed, Dec 02, 2009 at 01:32:06PM +0200, H??gander Jouni wrote:
    >> ext Mark Brown <> writes:
    >> > I'd add it as a fixed voltage regulator and either not specify the
    >> > voltage or specify the nominal voltage.
    >> I was preparing patch for this when I noticed that fixed voltage
    >> regulator can control only one regulator. Are you aware of any ongoing
    >> work to enable control for multiple regulators in
    >> fixed-voltage-regulator?
    > It's just a platform device configured with platform data, you can
    > instantiate as many fixed voltage regulators in your system as you care
    > to using the current driver.

    Yes, you are right. This was just my mistake in usage of the
    driver. Thanks for the clarification.

    Jouni Högander