lkml.org 
[lkml]   [2009]   [Jan]   [7]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
Date
SubjectRE: [PATCH] rtc-ds1307: True SMBus compatibility
> -----Original Message-----
> From: Ed Swierk [mailto:eswierk@aristanetworks.com]
> Sent: Tuesday, January 06, 2009 11:14 PM
> To: BARRE Sebastien
> Cc: linux-i2c@vger.kernel.org; David Brownell; Alessandro Zummo; linux-
> kernel@vger.kernel.org; Andrew Morton
> Subject: Re: [PATCH] rtc-ds1307: True SMBus compatibility
>
> On Tue, Jan 6, 2009 at 5:35 AM, BARRE Sebastien <sbarre@sdelcc.com> wrote:
> > I've read your patch quicly, I will test it on my board as soon as
> possible.
>
> Thanks.
>
> > You can delete the next 3 lines, they are not useful:
> >
> >> + ret = ds1307_read_block_data_once(client, command, length,
> currvalues);
> >> + if (ret < 0)
> >> + return ret;
>
> Oops! Here is an updated patch with these lines removed, and a minor
> formatting fix.
>
> Signed-off-by: Ed Swierk <eswierk@aristanetworks.com>
>
> --Ed

I've tested the patch on my geode LX board with a DS1307 device.
It works well for me.

However I think writing the clock one byte at a time could cause strange behavior when using alarms on device like ds1337.

Tested-by: Sébastien Barré <sbarre@sdelcc.com>

--
Sébastien Barré
Bureau d'étude - Développement
SDEL Contrôle Commande
D2A - Rue Nungesser et Coli
44860 Saint Aignan de Grand Lieu
FRANCE
Tél : +33(0)2 40 84 50 88
Fax : +33(0)2 40 84 51 10


\
 
 \ /
  Last update: 2009-01-07 15:25    [W:0.061 / U:7.844 seconds]