SubjectRe: [PATCH] power_supply: support CHARGE_NOW in OLPC battery
Ok, CC'ing Richard as I should've done in the first place...



On Thu, 8 May 2008 14:51:45 +0400
Anton Vorontsov <avorontsov@ru.mvista.com> wrote:

> On Thu, May 08, 2008 at 12:34:54AM -0400, Andres Salomon wrote:
> >
> > This is originally based on a patch by
> > David Woodhouse <dwmw2@infradead.org>. Add support for
> > PROP_CHARGE_NOW by querying the ACR (accumulated current register)
> > from the EC.
> >
> > Signed-off-by: Andres Salomon <dilinger@debian.org>
> > ---
>
> Hi Andres,
>
> > drivers/power/olpc_battery.c | 10 +++++++++-
> > 1 files changed, 9 insertions(+), 1 deletions(-)
> >
> > diff --git a/drivers/power/olpc_battery.c
> > b/drivers/power/olpc_battery.c index e3f6ec8..517dacd 100644
> > --- a/drivers/power/olpc_battery.c
> > +++ b/drivers/power/olpc_battery.c
> > @@ -19,7 +19,7 @@
> >
> > #define EC_BAT_VOLTAGE 0x10 /* uint16_t,
> > *9.76/32, mV */ #define EC_BAT_CURRENT 0x11 /*
> > int16_t, *15.625/120, mA */ -#define EC_BAT_ACR 0x12
> > +#define EC_BAT_ACR 0x12 /* int16_t,
> > *416.667, µAh */
>
> The hardware reports uAh * 416.667..?

Perhaps. Richard informs me that this might be incorrect. Richard,
would you care to clarify exactly what the ACR register value
contains? It sounds like we can't get uAh without taking two reads over
time and computing them.

Bonus points if one of us remembers to update
http://wiki.laptop.org/go/Ec_specification with the information. :)

The code snippet above is mangled due to wrapping. It was originally:

-#define EC_BAT_ACR 0x12
+#define EC_BAT_ACR 0x12 /* int16_t, *416.667, µAh */



>
> > #define EC_BAT_TEMP 0x13 /* uint16_t,
> > *100/256, °C */ #define EC_AMB_TEMP 0x14 /*
> > uint16_t, *100/256, °C */ #define EC_BAT_STATUS
> > 0x15 /* uint8_t, bitmask */ @@ -289,6 +289,13 @@
> > static int olpc_bat_get_property(struct power_supply *psy, ec_word
> > = be16_to_cpu(ec_word); val->intval = ec_word * 100 / 256;
> > break;
> > + case POWER_SUPPLY_PROP_CHARGE_NOW:
> > + ret = olpc_ec_cmd(EC_BAT_ACR, NULL, 0, (void
> > *)&ec_word, 2);
> > + if (ret)
> > + return ret;
> > +
> > + val->intval = be16_to_cpu(ec_word);
>
> But you didn't convert it to the uAh, I think you should.


We have logic in userspace that converts ACR to a useful number; for
our purposes, we'd just like to read the raw ACR values.

Perhaps CHARGE_NOW is the wrong thing to be using, if we can't get
uAh and CHARGE_* requires that unit.


>
> > + break;
> > case POWER_SUPPLY_PROP_SERIAL_NUMBER:
> > ret = olpc_ec_cmd(EC_BAT_SERIAL, NULL, 0, (void
> > *)&ser_buf, 8); if (ret)
> > @@ -317,6 +324,7 @@ static enum power_supply_property
> > olpc_bat_props[] = { POWER_SUPPLY_PROP_TEMP_AMBIENT,
> > POWER_SUPPLY_PROP_MANUFACTURER,
> > POWER_SUPPLY_PROP_SERIAL_NUMBER,
> > + POWER_SUPPLY_PROP_CHARGE_NOW,
> > };
> >
> > /* EEPROM reading goes completely around the power_supply API,
> > sadly */
>
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/

\
 
 \ /
  Last update: 2008-05-08 18:59    [W:0.083 / U:0.584 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site