Messages in this thread Patch in this message | | | From | Bjorn Helgaas <> | Subject | serial: add PNP ID GVC0303 for Archtek 3334BRV ISA modem | Date | Mon, 25 Feb 2008 09:15:27 -0700 |
| |
Thomas Lehmann <thomas.lehmann@alumni.tu-berlin.de> verified that this entry works.
Signed-off-by: Bjorn Helgaas <bjorn.helgaas@hp.com>
Index: work6/drivers/serial/8250_pnp.c =================================================================== --- work6.orig/drivers/serial/8250_pnp.c 2008-02-20 16:55:04.000000000 -0700 +++ work6/drivers/serial/8250_pnp.c 2008-02-25 09:04:41.000000000 -0700 @@ -91,6 +91,8 @@ /* Archtek America Corp. */ /* Archtek SmartLink Modem 3334BT Plug & Play */ { "GVC000F", 0 }, + /* Archtek SmartLink Modem 3334BRV 33.6K Data Fax Voice */ + { "GVC0303", 0 }, /* Hayes */ /* Hayes Optima 288 V.34-V.FC + FAX + Voice Plug & Play */ { "HAY0001", 0 },
| |