lkml.org 
[lkml]   [2008]   [Jan]   [21]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectW1: w1_slave units, standardize 1C or .001C? Break API
The ds18b20 one wire temperature sensor conversion routine is
returning the units in degrees C while the ds1820 (ds18s20) is
returning it in .001 degrees C. 20C vs 20312C. Once you know the
units I'm liking the latter as it gives a higher precision. Time to
break user applications so the driver can give the temperature in the
same units for both sensors.

I only have the ds18b20 sensor model. Here is the current output from
the sys file for this sensor.
/sys/devices/w1_bus_master1/28-0000000e84a2/w1_slave
45 01 4b 46 7f ff 0b 10 84 : crc=84 YES
45 01 4b 46 7f ff 0b 10 84 t=20

I ran the example data from the specification for the ds1820 through
it's conversion routine and found that t= was 1000 times the value.
What should the displayed units be?

This is the same ds18b20 conversion *1000. Is everyone ok or is any
objecting to .001 degrees C for the units? Patch will follow. The
.001 C does truncate one bit of precision from the ds18b20 by the way.

45 01 4b 46 7f ff 0b 10 84 : crc=84 YES
45 01 4b 46 7f ff 0b 10 84 t=20312

--
David Fries <david@fries.net>
http://fries.net/~david/ (PGP encryption key available)


\
 
 \ /
  Last update: 2008-01-22 00:29    [W:0.063 / U:0.104 seconds]