Messages in this thread | | | Date | Thu, 30 Aug 2007 11:01:44 +0100 | From | Alan Cox <> | Subject | Re: [PATCH] Override 80-wire cable detection for Toshiba S1800-814 |
| |
> Wow! I have been running 80wire cable detection override on 40wire cables > for quite some time without any problem, but I never thought it to be legal > if the 40wire cable length is short enough.
Yes.
> How short does it have to be, and can't we have a kernel bootparm to override > the cable detection?
For most users the goal should be to automate behaviour. It should just work. - To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/
| |