    On Fri, 27 Jun 2003, Larry McVoy wrote:

    > Anyone know what this means? This is from the supposedly superduper
    > rackspace machine which has a Mylex SCSI RAID (see below):
    >
    > DAC960#0: Physical Device 0:0 Sense Data Received
    > DAC960#0: Physical Device 0:0 Request Sense: Sense Key = 3, ASC = 11, ASCQ = 00
    > DAC960#0: Physical Device 0:0 Request Sense: Information = 0380A6CA 00000000
    > DAC960#0: Physical Device 0:0 Sense Data Received
    > DAC960#0: Physical Device 0:0 Request Sense: Sense Key = 3, ASC = 11, ASCQ = 00
    > DAC960#0: Physical Device 0:0 Request Sense: Information = 0380A6CA 00000000
    > DAC960#0: Physical Device 0:0 Errors: Parity = 0, Soft = 0, Hard = 0, Misc = 0
    > DAC960#0: Physical Device 0:0 Errors: Timeouts = 0, Retries = 0, Aborts = 0, Predicted = 0

    3h - MEDIUM ERROR: indicates that the command terminated with a
    non-recovered error caused by a flaw in the medium (the medium depends on
    the device type)

    Have to lookup the asc and ascq with ibm, as it varies by manufacturer.

    0Bh 01h DTLPWRSOMCAE Warning - specified temperature exceeded

    My guess is that you're seeing a temperature warning on a drive.

    Which makes sense with the overheated server room.

    Mike

    -
    To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
    the body of a message to majordomo@vger.kernel.org
    More majordomo info at http://vger.kernel.org/majordomo-info.html
    Please read the FAQ at http://www.tux.org/lkml/

    \
     
     \ /
      Last update: 2005-03-22 13:36    [W:0.019 / U:2.180 seconds]
    ©2003-2016 Jasper Spaans. hosted at Digital OceanAdvertise on this site