Thanks for the answers. Also, it is 2.4.19-rc3aa3 not whats in the subject.
The man page for badblocks encourages me to use e2fsck -c to run badblocks and to not run it directly. That, in addition to the hint from Alan that I was testing the incorrect range with badblocks lead to wanting to run e2fsck -c -c /dev/vg01/biglv. That lead to:
kernel: lvm -- lvm_blk_ioctl: unknown command 0x24b last message repeated 1443 times message repeated 1422 times
Then I thought, e2fsck works on filesystems and badblocks works on partitions so maybe this is not a good idea after all? What are the correct numbers to feed to badblocks to get it to test that portion of the disk?
Then some of these popped up a few minutes later:
smartd: Device: /dev/hda, S.M.A.R.T. Attribute: 231 Changed 11 smartd: Device: /dev/hde, S.M.A.R.T. Attribute: 231 Changed 8 smartd: Device: /dev/hdg, S.M.A.R.T. Attribute: 7 Changed -53
This clued me into the fact I had previously enabled this SMART on this box. I don't know much about SMART and I can't seem to find much about which of the below errors are truly fatal and whats normal. I did a short self test too.
I see the raw read error rate is 0 but it failed the self test in the read element!?
Is 11964485 a large number for Hardware ECC Recovered?
The drive is totally pooched I guess? Any light you could shed on which of the below numbers are the tell-tale signs that the drive is dying would be appreciated.
# smartctl -a /dev/hdg Device: MAXTOR 6L080J4 Supports ATA Version 5 Drive supports S.M.A.R.T. and is enabled Check S.M.A.R.T. Passed.
General Smart Values: Off-line data collection status: (0x00) Offline data collection activity was never started Self-test execution status: ( 112) The previous self-test completed having failed the read element of the test Total time to complete off-line data collection: ( 34) Seconds Offline data collection Capabilities: (0x1b)SMART EXECUTE OFF-LINE IMMEDIATE Automatic timer ON/OFF support Suspend Offline Collection upon new command Offline surface scan supported Self-test supported Smart Capablilities: (0x0003) Saves SMART data before entering power-saving mode Supports SMART auto save timer Error logging capability: (0x01) Error logging supported Short self-test routine recommended polling time: ( 2) Minutes Extended self-test routine recommended polling time: ( 40) Minutes
Vendor Specific SMART Attributes with Thresholds: Revision Number: 11 Attribute Flag Value Worst Threshold Raw Value ( 1)Raw Read Error Rate 0x0029 100 253 020 0 ( 3)Spin Up Time 0x0027 063 063 020 4659 ( 4)Start Stop Count 0x0032 100 100 008 192 ( 5)Reallocated Sector Ct 0x0033 097 097 020 18 ( 7)Seek Error Rate 0x000b 100 047 023 0 ( 9)Power On Hours 0x0012 096 096 001 2980 ( 10)Spin Retry Count 0x0026 100 100 000 0 ( 11)Calibration Retry Count 0x0013 100 100 020 0 ( 12)Power Cycle Count 0x0032 100 100 008 166 ( 13)Read Soft Error Rate 0x000b 100 100 023 0 (194)Temperature 0x0022 082 077 042 48 (195)Hardware ECC Recovered 0x001a 100 005 000 11964485 (196)Reallocated Event Count 0x0010 100 100 020 0 (197)Current Pending Sector 0x0032 100 100 020 3 (198)Offline Uncorrectable 0x0010 100 253 000 0 (199)UDMA CRC Error Count 0x001a 197 197 000 3 SMART Error Log: SMART Error Logging Version: 1 Error Log Data Structure Pointer: 04 ATA Error Count: 109 Non-Fatal Count: 0
Thanks,
Shane