On Thu, 28 Feb 2002, lonely wolf wrote:
> Mark Hahn wrote:
[...]
> > well, 109 MB/s is pretty low for buffer-cache reads; this reflects
> > the relative crippled-ness of your cpu/dram/chipset.
>
> well... i would't name a Celeron 900 MHz crippled. PC133 is the best the
> board gets... and now the speed is lower then the previous server which was
> an Athlon 600 pluggede in an Asus VIA KX133 based mobo.

I don't really see why you're expecting a performance breakthru downgrading
from Athlon to Celeron... many all-in-one MB (targeted to Celeron system)
are somewhat crippled and CPU MHz mean close to nothing for I/O performance
(or performance in general - read some papers explaining that on 200MHz
PentiumPro systems the bottleneck was RAM bandwidth!)

The buffer-cache reads timing (Mark was referring to) is sometimes a
good index:

Timing buffer-cache reads: 128 MB in 0.80 seconds =160.00 MB/sec
Timing buffered disk reads: 64 MB in 1.79 seconds = 35.75 MB/sec

(Athlon 700 slot-A system, not idle. I've seen 165+. Also note disk b/w.)

Timing buffer-cache reads: 128 MB in 0.58 seconds =220.69 MB/sec
Timing buffered disk reads: 64 MB in 1.85 seconds = 34.59 MB/sec

(Athlon 1333 DDR system, not idle. On initlevel 1 I've seen 245+)

Now, 220 vs 109 is a lot. But even 160 vs 109 is. Even the slowest system
I've seen (Duron 700MHz) was above 140. I bet your old Althon system
was capable of at least 145/150. So you downgraded, that's all.

rule 1: don't buy MB with integrated (shared mem) video chips;
rule 2: use DDR capable MB and CPU, @ 133MHz (or 266 on ad material);
rule 3: use SCSI if you can afford it. But ATA is fine on low-end.

>
> > doesn't the i815 have integrated video,
>
> yes
>
> > and if so, are you using it,
>
> yes
>
> > and if so, do you have the optional "display cache"?
>
> couldn't find any BIOS setting for that. where should it be ?
>
> > without the DC, video steals quite a lot of dram bandwidth...
>
> the machine is (should be) a NFS server, I couldn't care less about the
> video

it manages to steal mem b/w anyway.

Don't use that MB (and Celerons) for servers.

.TM.
--
____/ ____/ /
/ / / Marco Colombo
___/ ___ / / Technical Manager
/ / / ESI s.r.l.
_____/ _____/ _/ Colombo@ESI.it

-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/

\
 
 \ /
  Last update: 2005-03-22 13:21    [W:0.270 / U:0.144 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site