Messages in this thread |  | | From | Marvin Justice <> | Subject | Re: DMA problem (?) w/2.4.6-xfs and ServerWorks OSB4 Chipset | Date | Sun, 30 Sep 2001 15:37:16 -0500 |
| |
The error :
Curious - OSB4 thinks the DMA is still running. OSB4 wait exit
appears to occur during the "rewrite" phase of Bonnie++ every time we run it. The setup is a Tyan 2515 with a Seagate ST310211A drive. Bonnie ran for ~48 hours on 2.4.10 without slowdown (I assume this is because the extra check in -ac isn't present) but there was some file system corruption after the 1st 24 hours:
EXT2-fs error (device ide0(3,6)): ext2_free_blocks: Freeing blocks not in datazone - block = 2138996092, count = 1
Here's the lspci:
00:00.0 Host bridge: ServerWorks CNB20LE (rev 06) Flags: bus master, medium devsel, latency 32
00:00.1 Host bridge: ServerWorks CNB20LE (rev 06) Flags: bus master, medium devsel, latency 16
[snip]
00:0f.0 ISA bridge: ServerWorks OSB4 (rev 50) Subsystem: ServerWorks OSB4 Flags: bus master, medium devsel, latency 0
00:0f.1 IDE interface: ServerWorks: Unknown device 0211 (prog-if 8a [Master SecP PriP]) Flags: bus master, medium devsel, latency 64 I/O ports at ffa0 [size=16]
-- Marvin Justice Software Developer BOXX Technologies, Inc. www.boxxtech.com 512-235-6318 (V) 412-835-0434 (F) - To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/
|  |