Hi, I am facing 2 problems in Linux 2.2.16-22: [1] In the server program (tmgr_main1.c) attached herewith, i am waiting on events on the select system call on 3 sockets.
First I run the server program and its 3 client programs. If do a sendto in this program just before waiting for select or do a sendto in response to read events received by select, the message sent goes to the respective client and the programs work perfectly fine.
However If i run only the server and do not run the client programs, then the sendto done in the server program sends a message/event to the server itself ( which is waiting on events on that sockfd also) .
When i tried the above thing on SunOS 5.5.1 it worked perfectly fine!
(See attached file: server.c)
The output of this program is as follows: [npunmia@msatpd1 tm1]$ ./a.out
In Test Manager main function ! Signal Handler installed! Message sent to MRS! Waiting on select system call.... Data received from MRS! Error in receive! Servicing a MRS request! Message received = ?c Waiting on select system call.... Shutting down the test manager! [npunmia@msatpd1 tm1]$
[2] The second problem occurs when i do a sendto 2 or more times in this server program. This time also I run only the server and do not run the destination/clients programs. The point to note here is that i get a Connection Refused error every second time i do a sendto! The first time the message is sent correctly to the client , the second time i get Connection Refused error , third time the message is sent correctly to the client, and so on. (I have commented the second sendto before select . To try problem no. 2 you can remove the comments and run it) a) Why am i not getting a connection refused error consistently every time i do a sendto? b) Why at all am i getting a connection refused error in UDP in the first place?? c) When i try the above thing on SunOS, the message is sent from the server correctly every time, even though the client processes are not alive and i do not get any error!!!
The output on running the above program(remove the comments from the second sendto before select) is as follows:
[npunmia@msatpd1 tm1]$ ./a.out In Test Manager main function ! Signal Handler installed! Message sent to MRS! Error in send to MRS Error: Connection refused Waiting on select system call.... Shutting down the test manager! [npunmia@msatpd1 tm1]$
Regards, Niraj Punmia,