Messages in this thread |  | | Date | Thu, 15 Nov 2001 11:25:11 -0800 (PST) | From | Dan Hollis <> | Subject | Re: [lm_sensors] wrong sensors readings from w83782d on Tyan Dual K7/Thunder |
| |
On Thu, 15 Nov 2001, Hans-Peter Jansen wrote: > Readings from temp2 are always lower than from 1 and 3. > BIOS says: > temp1 = cpu0 > temp2 = cpu1 > temp3 = chassis
Yes. One cpu is generally right below the power supply so the airflow is obstructed or something, and it runs warmer than cpu0. Everyone's s2460 is like this.
temp1: +41.0 C (limit = +2 C, hysteresis = +64 C) sensor = 3904 transistor temp2: +39 C (limit = +80 C, hysteresis = +75 C) sensor = 3904 transistor temp3: +42 C (limit = +80 C, hysteresis = +75 C) sensor = 3904 transistor
-Dan -- [-] Omae no subete no kichi wa ore no mono da. [-]
- To unsubscribe from this list: send the line "unsubscribe linux-kernel" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html Please read the FAQ at http://www.tux.org/lkml/
|  |