SubjectRe: [PATCH] iio: dac: ad5592r: fix temperature scale
On Tue, Apr 30, 2024 at 9:59 AM Jonathan Cameron
<Jonathan.Cameron@huawei.com> wrote:
>
> On Tue, 30 Apr 2024 09:13:30 -0400
> marc.ferland@gmail.com wrote:
>
> > From: Marc Ferland <marc.ferland@sonatest.com>
> >
> > For temperature readings, the remainder is returned as nano Celsius
> > _but_ we mark it as IIO_VAL_INT_PLUS_MICRO. This results in incorrect
> > temperature reporting through hwmon for example. I have a board here
> > which reports the following when running 'sensors':
> >
> > iio_hwmon-isa-0000
> > Adapter: ISA adapter
> > temp1: +93.3°C
> >
> > With the patch applied, it returns the correct temperature:
> >
> > iio_hwmon-isa-0000
> > Adapter: ISA adapter
> > temp1: +30.5°C
> >
> > Signed-off-by: Marc Ferland <marc.ferland@sonatest.com>
>
> IIO temperature units are milli celcius, so I'm not following
> the argument here. The driver might be reporting in pico celcius
> I suppose? Call out that this is the scale factor though, so
> it corresponds to 1LSB hence a small number is certainly plausible..
>
> Reasonable to argue it's taking the integer and dividing by 10^9 hence
> INT_PLUS_NANO is the right answer, but it isn't nano celsius.
>

Oups! you're obviously right. I'll update my commit message and resend.
Marc

\
 
 \ /