Messages in this thread | | | Date | Thu, 25 Apr 2024 17:33:38 +0700 | Subject | Re: [PATCH v2 3/3] dt-bindings: hwmon: max31790: Add maxim,pwmout-pin-as-tach-input property | From | Chanh Nguyen <> |
| |
On 24/04/2024 00:02, Conor Dooley wrote: > [EXTERNAL EMAIL NOTICE: This email originated from an external sender. Please be mindful of safe email handling and proprietary information protection practices.] >
Sorry Conor, there may be confusion here. I mean the mapping of the PWM output to the TACH input, which is on the MAX31790, and it is not sure a common feature on all fan controllers.
I would like to open a discussion about whether we should use the tach-ch property on the fan-common.yaml
I'm looking forward to hearing comments from everyone. For me, both tach-ch and vendor property are good.
Thank you, Conor!
| |