Messages in this thread | ![/](/images/icornerl.gif) | | Date | Fri, 12 Jan 2024 08:08:15 +0800 | Subject | Re: [PATCH v7 2/4] dt-bindings: clock: sophgo: support SG2042 | From | Chen Wang <> |
| |
On 2024/1/12 0:58, Conor Dooley wrote: > On Thu, Jan 11, 2024 at 04:00:04PM +0800, Chen Wang wrote: >> hi,Conor, >> >> There are four types of clocks for SG2042 and following are where their >> control registers are defined in: >> >> PLL:all in SYS_CTRL >> DIV: all in CLOCK >> GATE: some are in SYS_CTRL, some others are in CLOCK > When you say "some", do you meant some entire clocks are in SYS_CTRL and > some entire clocks are in the CLOCKS? Or do you meant that for a given > clock, some registers are in SYS_CTRL and some are in CLOCK? It's the > first option, right?
It's the first option.
>> MUX: all in CLOCK