lkml.org 
[lkml]   [2023]   [Jan]   [30]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH v2 2/2] pwm: sifive: change the PWM controlled LED algorithm
Date
The `frac` variable represents the pulse inactive time, and the result of
this algorithm is the pulse active time. Therefore, we must reverse the
result.

The reference is SiFive FU740-C000 Manual[0].

[0]: https://sifive.cdn.prismic.io/sifive/1a82e600-1f93-4f41-b2d8-86ed8b16acba_fu740-c000-manual-v1p6.pdf

Signed-off-by: Nylon Chen <nylon.chen@sifive.com>
---
drivers/pwm/pwm-sifive.c | 1 +
1 file changed, 1 insertion(+)

diff --git a/drivers/pwm/pwm-sifive.c b/drivers/pwm/pwm-sifive.c
index 62b6acc6373d..a5eda165d071 100644
--- a/drivers/pwm/pwm-sifive.c
+++ b/drivers/pwm/pwm-sifive.c
@@ -158,6 +158,7 @@ static int pwm_sifive_apply(struct pwm_chip *chip, struct pwm_device *pwm,
frac = DIV64_U64_ROUND_CLOSEST(num, state->period);
/* The hardware cannot generate a 100% duty cycle */
frac = min(frac, (1U << PWM_SIFIVE_CMPWIDTH) - 1);
+ frac = (1U << PWM_SIFIVE_CMPWIDTH) - 1 - frac;

mutex_lock(&ddata->lock);
if (state->period != ddata->approx_period) {
--
2.36.1
\
 
 \ /