Messages in this thread | | | Date | Mon, 2 Jan 2023 16:23:34 +0100 | From | Philipp Zabel <> | Subject | Re: [PATCH v2 5/6] dt-bindings: clock: Add D1 CAN bus gates and resets |
| |
On Sat, Dec 31, 2022 at 05:14:28PM -0600, Samuel Holland wrote: > The D1 CCU contains gates and resets for two CAN buses. While the CAN > bus controllers are only documented for the T113 SoC, the CCU is the > same across all SoC variants. > > Reviewed-by: Andre Przywara <andre.przywara@arm.com> > Signed-off-by: Samuel Holland <samuel@sholland.org> [...] > diff --git a/include/dt-bindings/reset/sun20i-d1-ccu.h b/include/dt-bindings/reset/sun20i-d1-ccu.h > index de9ff5203239..f8001cf50bf1 100644 > --- a/include/dt-bindings/reset/sun20i-d1-ccu.h > +++ b/include/dt-bindings/reset/sun20i-d1-ccu.h > @@ -73,5 +73,7 @@ > #define RST_BUS_DSP_CFG 63 > #define RST_BUS_DSP_DBG 64 > #define RST_BUS_RISCV_CFG 65 > +#define RST_BUS_CAN0 66 > +#define RST_BUS_CAN1 67
Acked-by: Philipp Zabel <p.zabel@pengutronix.de>
regards Philipp
| |