Messages in this thread | | | From | Xinlei Lee (李昕磊) <> | Subject | Re: [PATCH v2 2/3] drm/panel: boe-tv101wum-nl6: Reduce lcm_reset to send initial code time | Date | Thu, 12 Jan 2023 09:41:33 +0000 |
| |
On Tue, 2023-01-10 at 10:20 +0100, AngeloGioacchino Del Regno wrote: > Il 10/01/23 06:54, xinlei.lee@mediatek.com ha scritto: > > From: Xinlei Lee <xinlei.lee@mediatek.com> > > > > Since the panel spec stipulates that the time from lcm_reset to DSI > > to > > send the initial code should be greater than 6ms and less than > > 40ms, > > so reduce the delay before sending the initial code and avoid panel > > exceptions. > > Please change the commit title to describe what you're doing. > > drm/panel: boe-tv101wum-nl6: Remove extra delay in init commands > > > ....and the commit description should also contain something like > > Reduce the delay after LCM reset by removing an extra delay in the > initialization commands array. The required delay of at least 6ms > after > reset is guaranteed by boe_panel_prepare(). > > Regards, > Angelo >
Hi Angelo:
Thanks for your suggestions and careful revisions, I will revise my commit description.
Best Regards! xinlei
| |