Messages in this thread Patch in this message | | | From | richard.gong@linux ... | Subject | [PATCHv5 1/7] firmware: stratix10-svc: reset COMMAND_RECONFIG_FLAG_PARTIAL to 0 | Date | Tue, 9 Feb 2021 16:20:27 -0600 |
| |
From: Richard Gong <richard.gong@intel.com>
Clean up COMMAND_RECONFIG_FLAG_PARTIAL flag by resetting it to 0, which aligns with the firmware settings.
Fixes: 36847f9e3e56 ("firmware: stratix10-svc: correct reconfig flag and timeout values") Signed-off-by: Richard Gong <richard.gong@intel.com> --- v5: new add, add the missing standalone patch --- include/linux/firmware/intel/stratix10-svc-client.h | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/include/linux/firmware/intel/stratix10-svc-client.h b/include/linux/firmware/intel/stratix10-svc-client.h index a93d859..f843c6a 100644 --- a/include/linux/firmware/intel/stratix10-svc-client.h +++ b/include/linux/firmware/intel/stratix10-svc-client.h @@ -56,7 +56,7 @@ * COMMAND_RECONFIG_FLAG_PARTIAL: * Set to FPGA configuration type (full or partial). */ -#define COMMAND_RECONFIG_FLAG_PARTIAL 1 +#define COMMAND_RECONFIG_FLAG_PARTIAL 0 /** * Timeout settings for service clients: -- 2.7.4
| |