Messages in this thread | | | Subject | Re: [PATCH 1/2] hwmon: add Delta AHE-50DC fan control module driver | From | Guenter Roeck <> | Date | Mon, 6 Dec 2021 15:02:49 -0800 |
| |
On 12/6/21 2:44 PM, Zev Weiss wrote: > This device is an integrated module of the Delta AHE-50DC Open19 power > shelf. For lack of proper documentation, this driver has been developed > referencing an existing (GPL) driver that was included in a code release > from LinkedIn [1]. It provides four fan speeds, four temperatures, and > one voltage reading, as well as a handful of warning and fault > indicators. > > [1] https://github.com/linkedin/o19-bmc-firmware/blob/master/meta-openbmc/meta-linkedin/meta-deltapower/recipes-kernel/fancontrol-mod/files/fancontrol.c > > Signed-off-by: Zev Weiss <zev@bewilderbeest.net> > ---
[ ... ]
> + > +static const u8 AHE50DC_FAN_TEMP_REGS[] = { 0x8d, 0x8e, 0x8f, 0xd0 }; > +static const u8 AHE50DC_FAN_SPEED_REGS[] = { 0x90, 0x91, 0x92, 0x93 }; > +static const u8 AHE50DC_FAN_FAN_STATUS_REGS[] = { 0x81, 0x82 }; > +#define AHE50DC_FAN_VIN_REG 0x88 > +#define AHE50DC_FAN_CHIP_STATUS_REG 0x79
PMBus registers:
PMBUS_STATUS_WORD = 0x79,
PMBUS_STATUS_FAN_12 = 0x81, PMBUS_STATUS_FAN_34 = 0x82,
PMBUS_READ_VIN = 0x88,
PMBUS_READ_TEMPERATURE_1 = 0x8D, PMBUS_READ_TEMPERATURE_2 = 0x8E, PMBUS_READ_TEMPERATURE_3 = 0x8F, PMBUS_READ_FAN_SPEED_1 = 0x90, PMBUS_READ_FAN_SPEED_2 = 0x91, PMBUS_READ_FAN_SPEED_3 = 0x92, PMBUS_READ_FAN_SPEED_4 = 0x93,
This is quite obviously a PMBus device. Why not use the PMBus driver ?