Messages in this thread | | | Subject | Re: [PATCH 09/10] arm64: tegra: Audio graph header for Tegra210 | From | Sameer Pujar <> | Date | Mon, 3 Aug 2020 17:36:52 +0530 |
| |
On 7/20/2020 10:21 AM, Kuninori Morimoto wrote: > External email: Use caution opening links or attachments > > > Hi Sameer > >>>> +&tegra_admaif { >>>> + admaif_port: port { >>>> + admaif0: endpoint@0 { >>>> + remote-endpoint = <&xbar_admaif0>; >>>> + }; >>>> + admaif1: endpoint@1 { >>>> + remote-endpoint = <&xbar_admaif1>; >>>> + }; >>> (snip) >>>> + admaif8: endpoint@8 { >>>> + remote-endpoint = <&xbar_admaif8>; >>>> + }; >>>> + admaif9: endpoint@9 { >>>> + remote-endpoint = <&xbar_admaif9>; >>>> + }; >>>> + }; >>>> +}; >>> I'm not familiar with your system, so, one question. >>> Does this ADMAIF has total 10 interface which is used in the same time ? >>> or select one of 10 connections when use ? >> One ore more ADMAIF interfaces can be used simultaneously. In fact all >> of them can be used at the same time. > Ah, sorry my questoin was not correct. > I want to clarify was that below. > > In my understanding, > if your system has 10 interfaces, > you need to create 10 ports, not 10 endpoints. > If your system has 1 interface, but is connected from 10 > devices, it has 1 port 10 endpoints.
OK, I see your point. I will work on re-organizing ports/endpoints and once tested will publish V2 for current series. Thanks for inputs.
> > Thank you for your help !! > > Best regards > --- > Kuninori Morimoto
| |