lkml.org 
[lkml]   [2020]   [Apr]   [7]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [RFC PATCH] coresight: dynamic-replicator: Fix handling of multiple connections
From
Date
On 04/07/2020 12:29 PM, Sai Prakash Ranjan wrote:
> Hi Suzuki,
>
> Thanks for looking into this issue.
>
> On 2020-04-07 15:54, Suzuki K Poulose wrote:
>> On 04/07/2020 10:46 AM, Sai Prakash Ranjan wrote:
>>
>> There seems to be two replicators back to back here. What is connected
>> to the other output of both of them ? Are there any TPIUs ? What happens
>> if you choose a sink on the other end of "swao_replicator" (ETB ?)
>>
>
> The other outport of swao replicator is connected to EUD which is a
> QCOM specific HW which can be used as a sink like USB.
> And the other outport of other replicator(replicator_out) is connected to
> TPIU.
>
>> After boot, what do the idfilter registers read for both the
>> replicators ?
>>
>
> Added some prints in replicator_probe.
>
>  replicator probe ret=-517 devname=6046000.replicator idfilter0=0x0
> idfilter1=0x0
>  replicator probe ret=0 devname=6b06000.replicator idfilter0=0xff
> idfilter1=0xff
>  replicator probe ret=0 devname=6046000.replicator idfilter0=0xff
> idfilter1=0xff

Curious to see how the idfilterX is set to 0:
if that is never used.
Or
if the user doesn't reset it back to 0xff.

Does your test ever touch EUD (enable the port for EUD at
swao-replicator) ? What are the values before you run your test ?


Suzuki

\
 
 \ /
  Last update: 2020-04-07 15:04    [W:0.040 / U:0.352 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site