Messages in this thread | ![/](/images/icornerl.gif) | | Date | Sun, 4 Aug 2019 17:04:14 +0200 | From | Andrew Lunn <> | Subject | Re: [PATCH net] net: dsa: mv88e6xxx: drop adjust_link to enabled phylink |
| |
On Wed, Jul 31, 2019 at 05:42:39PM +0200, Hubert Feurstein wrote: > We have to drop the adjust_link callback in order to finally migrate to > phylink. > > Otherwise we get the following warning during startup: > "mv88e6xxx 2188000.ethernet-1:10: Using legacy PHYLIB callbacks. Please > migrate to PHYLINK!" > > The warning is generated in the function dsa_port_link_register_of in > dsa/port.c: > > int dsa_port_link_register_of(struct dsa_port *dp) > { > struct dsa_switch *ds = dp->ds; > > if (!ds->ops->adjust_link) > return dsa_port_phylink_register(dp); > > dev_warn(ds->dev, > "Using legacy PHYLIB callbacks. Please migrate to PHYLINK!\n"); > [...] > } > > Signed-off-by: Hubert Feurstein <h.feurstein@gmail.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Andrew