lkml.org 
[lkml]   [2019]   [Feb]   [15]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH net-next v2 3/3] enetc: Add ENETC PF level external MDIO support
On Fri, Feb 15, 2019 at 12:10:14PM +0200, Claudiu Manoil wrote:
> Each ENETC PF has its own MDIO interface, the corresponding
> MDIO registers are mapped in the ENETC's Port register block.
> The current patch adds a driver for these PF level MDIO buses,
> so that each PF can manage directly its own external link.
>
> Signed-off-by: Alex Marginean <alexandru.marginean@nxp.com>
> Signed-off-by: Claudiu Manoil <claudiu.manoil@nxp.com>
> ---
> v2 - used readx_poll_timeout()
> - added mdio node child to the port node

Hi Claudiu

Please document this in the device tree binding.

> + /* return all Fs if nothing was there */
> + if (enetc_rd_reg(&regs->mdio_cfg) & MDIO_CFG_RD_ER) {
> + dev_err(&bus->dev,
> + "Error while reading PHY%d reg at %d.%hhu\n",
> + phy_id, dev_addr, regnum);
> + return 0xffff;

I'm not sure you want a dev_err() here. The device tree binding allows
you to have a phy node without a reg value. When that happens, the
core code will scan all 32 addresses to find the PHY. This is going to
spam the log. dev_dbg() might be better.

Andrew

\
 
 \ /
  Last update: 2019-02-15 14:35    [W:0.068 / U:0.280 seconds]