lkml.org 
[lkml]   [2018]   [Jun]   [6]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH 1/4] serial: 8250: Copy em485 from port to real port.
From
Date
Il 06/06/2018 20:55, Matwey V. Kornilov ha scritto:
> 2018-06-06 16:11 GMT+03:00 Andy Shevchenko <andriy.shevchenko@linux.intel.com>:
>> On Wed, 2018-06-06 at 14:15 +0200, Giulio Benetti wrote:
>>> Il 06/06/2018 13:56, Andy Shevchenko ha scritto:
>>>> On Wed, 2018-06-06 at 11:49 +0200, Giulio Benetti wrote:
>>>>> em485 gets lost during
>>>>>
>>>>> Copy em485 to final uart port.
>>>>>
>>>>
>>>> Is it needed at all?
>>>>
>>>> The individual driver decides either to use software emulation (and
>>>> calls explicitly serial8250_em485_init() for that) or do HW assisted
>>>> stuff.
>>>
>>> In 8250_dw.c, during probe(), I need to call dw8250_rs485_config()
>>> against local struct uart_8250_port uart = {};
>>> Inside serial8250_register_8250_port() not all uart fields are
>>> copied(em485 too).
>>> So after probe, em485 is NULL.
>>>
>>> Another way could be to call dw8250_rs485_config() against real uart
>>> port, after calling serial8250_register_8250_port(),
>>> would it make sense?
>>
>> Look at OMAP case closely. They have a callback to configure RS485 which
>> is called in uart_set_rs485_config() which is called whenever user
>> space does TIOCGRS485 IOCTL.
>>
>> So, it's completely driven by user space which makes sense by my
>> opinion.
>
> AFAIU, Giulio wants to add support for rs485-enabled-at-boot-time
> device tree option (see bindings/serial/rs485.txt for reference).

Yes, I want to add support for "rs485-enabled-at-boot-time" property,
maybe I had to write better commit log and a cover letter. Sorry.

> I suppose it is only important for use-case when rs485 used as slave
> (peripheral role).

It's important also for master, because RTS, if RTS_AFTER_SEND is set,
remains not asserted(trasnmission) until userspace opens that serial port.

Sorry again for not explaining myself well.

--
Giulio Benetti
CTO

MICRONOVA SRL
Sede: Via A. Niedda 3 - 35010 Vigonza (PD)
Tel. 049/8931563 - Fax 049/8931346
Cod.Fiscale - P.IVA 02663420285
Capitale Sociale € 26.000 i.v.
Iscritta al Reg. Imprese di Padova N. 02663420285
Numero R.E.A. 258642

\
 
 \ /
  Last update: 2018-06-06 21:15    [W:0.142 / U:0.880 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site