Messages in this thread | | | Date | Tue, 5 Jun 2018 11:23:34 +0530 | From | Viresh Kumar <> | Subject | Re: [PATCH V4] powercap/drivers/idle_injection: Add an idle injection framework |
| |
On 05-06-18, 07:48, Daniel Lezcano wrote: > As soon as we reach complete(), no timer can be set because of the > condition before.
Why not ? We aren't using any locks here and it is possible that run_duration_ms is set to 0 from idle_injection_stop() only after the first thread has restarted the hrtimer. Isn't it ?