Messages in this thread | | | Date | Tue, 22 May 2018 13:56:02 -0700 | From | Guenter Roeck <> | Subject | Re: [PATCH 1/5] Documentation: DT: Add optional 'timeout-sec' property for sp805 |
| |
On Tue, May 22, 2018 at 11:47:16AM -0700, Ray Jui wrote: > Update the SP805 binding document to add optional 'timeout-sec' > devicetree property > > Signed-off-by: Ray Jui <ray.jui@broadcom.com> > Reviewed-by: Scott Branden <scott.branden@broadcom.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
> --- > Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++ > 1 file changed, 2 insertions(+) > > diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt > index edc4f0e..f898a86 100644 > --- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt > +++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt > @@ -19,6 +19,8 @@ Required properties: > > Optional properties: > - interrupts : Should specify WDT interrupt number. > +- timeout-sec : Should specify default WDT timeout in seconds. If unset, the > + default timeout is 30 seconds > > Examples: > > -- > 2.1.4 >
| |