On Tue, 2018-04-10 at 18:18 +0800, Yu Chen wrote:
> @@ -5076,6 +5084,15 @@ void cmdline(int argc, char **argv)
> print_version();
> exit(0);
> break;
> + case 'x':
> + {
> + unsigned int loops = strtod(optarg, NULL);

It would make sense to error out here if you get a value <= 0.

> +
> + if (loops % 2)
> + loops++;

What is this for?

> + max_loops = loops;

Is the "loops" variable really needed? Can you strtod directly to
max_loops?

--
Best Regards,
Artem Bityutskiy
---------------------------------------------------------------------