lkml.org 
[lkml]   [2018]   [Mar]   [8]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH AUTOSEL for 3.18 53/53] clk: si5351: Rename internal plls to avoid name collisions
Date
From: Sergej Sawazki <sergej@taudac.com>

[ Upstream commit cdba9a4fb0b53703959ac861e415816cb61aded4 ]

This drivers probe fails due to a clock name collision if a clock named
'plla' or 'pllb' is already registered when registering this drivers
internal plls.

Fix it by renaming internal plls to avoid name collisions.

Cc: Sebastian Hesselbarth <sebastian.hesselbarth@gmail.com>
Cc: Rabeeh Khoury <rabeeh@solid-run.com>
Signed-off-by: Sergej Sawazki <sergej@taudac.com>
Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
---
drivers/clk/clk-si5351.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/clk/clk-si5351.c b/drivers/clk/clk-si5351.c
index 44ea107cfc67..8c8c2443f601 100644
--- a/drivers/clk/clk-si5351.c
+++ b/drivers/clk/clk-si5351.c
@@ -72,7 +72,7 @@ static const char * const si5351_input_names[] = {
"xtal", "clkin"
};
static const char * const si5351_pll_names[] = {
- "plla", "pllb", "vxco"
+ "si5351_plla", "si5351_pllb", "si5351_vxco"
};
static const char * const si5351_msynth_names[] = {
"ms0", "ms1", "ms2", "ms3", "ms4", "ms5", "ms6", "ms7"
--
2.14.1
\
 
 \ /