On Thu, Feb 15, 2018 at 07:05:56PM +0100, Giulio Benetti wrote:
> > If so, and if remember the captures properly, the sampling would occur
> > right before the rise, and not really around the fall.
> >
> > Would 2/3 be better here?
>
> Yes, you're right, 2/3 phase is better:
>
> 1/3 phase: https://pasteboard.co/H4VehON.png
> 2/3 phase: https://pasteboard.co/H4Veq8a.png
>
> Take a look at the bit in middle(yellow) sampled by clock(blue).
>
> Rising edge is almost in the middle of D0 bit.
>
> >
> > > According to scope captures above on both A20 and A33.
> > > Unfortunately I don't have other boards for the other SoCs to take captures.
> > >
> > > What do you think?
> >
> > I guess we can make that part applicable to all SoCs, we haven't seen
> > any significant differences on those part.
>
> So let's keep:
> - As normal(rising edge) => IO_POL_REG "0x2 => 2/3 phase"
> - As inverted(falling edge) => IO_POL_REG "0x0 => normal phase"

I was actually thinking 1/3 for rising, 2/3 for falling.

Maxime

--
Maxime Ripard, Bootlin (formerly Free Electrons)
Embedded Linux and Kernel engineering
http://bootlin.com