SubjectRe: [PATCH 2/3] i2c-axxia: check for error conditions first
On Mon, Dec 10, 2018 at 03:01:27PM +0000, Adamski, Krzysztof (Nokia - PL/Wroclaw) wrote:
> It was observed that when using seqentional mode contrary to the
> documentation, the SS bit (which is supposed to only be set if
> automatic/sequence command completed normally), is sometimes set
> together with NA (NAK in address phase) causing transfer to falsely be
> considered successful.
>
> My assumption is that this does not happen during manual mode since the
> controller is stopping its work the moment it sets NA/ND bit in status
> register. This is not the case in Automatic/Sequentional mode where it
> is still working to send STOP condition and the actual status we get
> depends on the time when the ISR is run.
>
> This patch changes the order of checking status bits in ISR - error
> conditions are checked first and only if none of them occurred, the
> transfer may be considered successful. This is required to introduce
> using of sequentional mode in next patch.
>
> Signed-off-by: Krzysztof Adamski <krzysztof.adamski@nokia.com>

Applied to for-next, thanks!