The PMU node has no working interrupt, as shown by this dtc warning:

arch/arm64/boot/dts/altera/socfpga_stratix10_socdk.dtb: Warning (interrupts_property): Missing interrupt-parent for /pmu

This adds an interrupt-parent property so we can correct parse
that interrupt number.

Signed-off-by: Arnd Bergmann <arnd@arndb.de>
---
If this looks ok, I'd apply it directly to the fixes branch
for 4.15, as the warning is one that was introduced in this
release.
---
arch/arm64/boot/dts/altera/socfpga_stratix10.dtsi | 1 +
1 file changed, 1 insertion(+)

diff --git a/arch/arm64/boot/dts/altera/socfpga_stratix10.dtsi b/arch/arm64/boot/dts/altera/socfpga_stratix10.dtsi
index 7c9bdc7ab50b..9db19314c60c 100644
--- a/arch/arm64/boot/dts/altera/socfpga_stratix10.dtsi
+++ b/arch/arm64/boot/dts/altera/socfpga_stratix10.dtsi
@@ -66,6 +66,7 @@
<&cpu1>,
<&cpu2>,
<&cpu3>;
+ interrupt-parent = <&intc>;
};

psci {
--
2.9.0
\
 
 \ /