lkml.org 
[lkml]   [2017]   [Jun]   [30]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: Where to update regulator register with initial voltage set by HW
On Thu, Jun 29, 2017 at 09:18:09AM +0200, Waldemar Rymarkiewicz wrote:

> Initially, on boot, the voltage is set by HW (sensing resistors). When
> OS starts and the reg driver registers regulator with the specific
> constraints uV_min and uV_max, regulator core will apply uV_min or
> uV_max if current (in regulator register) setting is not in the range.
> Normally, by default register holds min(voltage_table) which is
> different than the value set by HW (sensing resistors).

You shoudn't be specfiying a default value for the register, clearly
there is none as it is determined dynamically by the hardware when the
system boots.
[unhandled content-type:application/pgp-signature]
\
 
 \ /