SubjectRe: [PATCH] i2c: designware: Fix bogus sda_hold_time due to uninitialized vars
On Mon, May 22, 2017 at 07:46:55AM +0200, Jan Kiszka wrote:
> We need to initializes those variables to 0 for platforms that do not
> provide ACPI parameters. Otherwise, we set sda_hold_time to random
> values, breaking e.g. Galileo and IOT2000 boards.
>
> Fixes: 9d6408433019 ("i2c: designware: don't infer timings described by ACPI from clock rate")
> Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>

Applied to for-current, thanks!

[unhandled content-type:application/pgp-signature]
\
 
 \ /