Messages in this thread | | | Subject | Re: [PATCH v9 3/3] printk: fix double printing with earlycon | From | Aleksey Makarov <> | Date | Fri, 12 May 2017 00:17:18 +0300 |
| |
On 05/11/2017 02:32 PM, Sergey Senozhatsky wrote: > On (05/11/17 17:41), Sergey Senozhatsky wrote: > [..] >> Alexey, >> can we have preferred console at offset 0 (not at console_cmdline_cnt - 1) >> and restore the previous register_console() iteration order? > > btw, what if someone has configured the system as > console= non-braille non-braille braille non-braille? > "The last non-braille console is always the preferred one" > is not true in this case.
I don't quite follow what you think is problem here. The invariant keeps here, the code makes it always true. In this case the last console is non-braille and it is preferred. What is the problem?
Thank you Aleksey Makarov
| |