Messages in this thread Patch in this message | | | From | Jan Kiszka <> | Subject | [PATCH v2 3/7] serial: exar: Fix feature control register constants | Date | Wed, 8 Feb 2017 17:09:05 +0100 |
| |
According to the XR17V352 manual, bit 4 is IrDA control and bit 5 for 485. Fortunately, no driver used them so far.
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> --- include/uapi/linux/serial_reg.h | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-)
diff --git a/include/uapi/linux/serial_reg.h b/include/uapi/linux/serial_reg.h index 274d8fc..25b93a7 100644 --- a/include/uapi/linux/serial_reg.h +++ b/include/uapi/linux/serial_reg.h @@ -374,8 +374,8 @@ #define UART_EXAR_DVID 0x8d /* Device identification */ #define UART_EXAR_FCTR 0x08 /* Feature Control Register */ -#define UART_FCTR_EXAR_IRDA 0x08 /* IrDa data encode select */ -#define UART_FCTR_EXAR_485 0x10 /* Auto 485 half duplex dir ctl */ +#define UART_FCTR_EXAR_IRDA 0x10 /* IrDa data encode select */ +#define UART_FCTR_EXAR_485 0x20 /* Auto 485 half duplex dir ctl */ #define UART_FCTR_EXAR_TRGA 0x00 /* FIFO trigger table A */ #define UART_FCTR_EXAR_TRGB 0x60 /* FIFO trigger table B */ #define UART_FCTR_EXAR_TRGC 0x80 /* FIFO trigger table C */ -- 2.1.4
| |