SubjectRe: [PATCH v2 6/7] iio: adc: ina2xx: Align timestamp with conversion ready flag
On Thu, 21 Dec 2017 19:31:37 +0100
Stefan Brüns <stefan.bruens@rwth-aachen.de> wrote:

> As the timestamp is no longer (ab-)used to measure the function run time,
> it can be taken at the correct time, i.e. when the conversion has finished.
>
> Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de>
Applied.

Thanks,

Jonathan

> ---
>
> Changes in v2: None
>
> drivers/iio/adc/ina2xx-adc.c | 4 ++--
> 1 file changed, 2 insertions(+), 2 deletions(-)
>
> diff --git a/drivers/iio/adc/ina2xx-adc.c b/drivers/iio/adc/ina2xx-adc.c
> index 415e53b5c0a6..b7407ac91b59 100644
> --- a/drivers/iio/adc/ina2xx-adc.c
> +++ b/drivers/iio/adc/ina2xx-adc.c
> @@ -706,8 +706,6 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev)
> s64 time;
> unsigned int alert;
>
> - time = iio_get_time_ns(indio_dev);
> -
> /*
> * Because the timer thread and the chip conversion clock
> * are asynchronous, the period difference will eventually
> @@ -736,6 +734,8 @@ static int ina2xx_work_buffer(struct iio_dev *indio_dev)
>
> } while (!alert);
>
> + time = iio_get_time_ns(indio_dev);
> +
> /*
> * Single register reads: bulk_read will not work with ina226/219
> * as there is no auto-increment of the register pointer.

\
 
 \ /
  Last update: 2017-12-29 18:50    [W:0.064 / U:0.152 seconds]