lkml.org 
[lkml]   [2017]   [Dec]   [12]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH v1 3/7] iio: adc: ina2xx: Remove unneeded dummy read to clear CNVR flag
On Sun, 10 Dec 2017 21:53:42 +0100
Stefan Brüns <stefan.bruens@rwth-aachen.de> wrote:

> On Sunday, December 10, 2017 6:27:33 PM CET Jonathan Cameron wrote:
> > On Fri, 8 Dec 2017 18:41:48 +0100
> >
> > Stefan Brüns <stefan.bruens@rwth-aachen.de> wrote:
> > > Although the datasheet states the CNVR flag is cleared by reading the
> > > BUS_VOLTAGE register, it is actually cleared by reading any of the
> > > voltage/current/power registers.
> > >
> > > The behaviour has been confirmed by TI support:
> > > http://e2e.ti.com/support/amplifiers/current-shunt-monitors/f/931/p/647053
> > > /2378282
> > >
> > > Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de>
> >
> > I haven't checked the code thoroughly so there may well be something
> > stopping it but have you checked the case where the only channel enabled is
> > the timestamp?
> >
> > Obviously it makes little sense, but IIRC there is nothing in the core
> > preventing that happening.
>
> The timestamp is completely unrelated to the status register, so I fail to
> understand your question. Can you please clarify?

If you only have a timestamp, the trigger will still fire (I think)
but you'll do no reading at all from the device. If configured in this,
admittedly odd, way you should just get a stream of timestamps with no
data.

>
> This only removes a redundant read.
The question is whether it is redundant if we have no non timestamp
registers enabled.

I'll be honest, whilst I can't immediately spot any protection against
this in the core (and it definitely used to be possible), I'm not totally
sure it now is and don't have a system to hand to test against.

We had some debate a long time back on whether it made sense to have
only timestamps and I think we concluded it did as you might in theory
only care about the timing and not the data in some obscure cases.

Jonathan

>
> All channel combinations (w/ and w/o timestamp) work, but combinations not
> including the power register use less bus time now.
>
> Kind regards,
>
> Stefan
>

\
 
 \ /
  Last update: 2017-12-12 21:16    [W:0.066 / U:0.348 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site