Subject[PATCH] iio: fix pressure data output unit in hid-sensor-attributes
Date
From: "Kweh, Hock Leong" <hock.leong.kweh@intel.com>

According to IIO ABI definition, IIO_PRESSURE data output unit is
kilopascal:
http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio

This patch fix output unit of HID pressure sensor IIO driver from pascal to
kilopascal to follow IIO ABI definition.

Signed-off-by: Kweh, Hock Leong <hock.leong.kweh@intel.com>
---
.../iio/common/hid-sensors/hid-sensor-attributes.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
index e81f434..dc33c1d 100644
--- a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
+++ b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
@@ -56,8 +56,8 @@ static struct {
{HID_USAGE_SENSOR_ALS, 0, 1, 0},
{HID_USAGE_SENSOR_ALS, HID_USAGE_SENSOR_UNITS_LUX, 1, 0},

- {HID_USAGE_SENSOR_PRESSURE, 0, 100000, 0},
- {HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 1, 0},
+ {HID_USAGE_SENSOR_PRESSURE, 0, 100, 0},
+ {HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 0, 1000},
};

static int pow_10(unsigned power)
--