| From | Daniel Lezcano <> | Subject | [PATCH 01/93] clocksource/drivers/armada-370-xp: Make syscore_ops static | Date | Thu, 7 Jul 2016 10:00:34 +0200 |
| |
From: Ben Dooks <ben.dooks@codethink.co.uk>
The driver does not export armada_370_xp_timer_syscore_ops so make it static to fix the following warning:
drivers/clocksource/time-armada-370-xp.c:249:20: warning: symbol 'armada_370_xp_timer_syscore_ops' was not declared. Should it be static?
Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Acked-by: Gregory CLEMENT <gregory.clement@free-electrons.com> --- drivers/clocksource/time-armada-370-xp.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clocksource/time-armada-370-xp.c b/drivers/clocksource/time-armada-370-xp.c index d93ec3c..601dbf74 100644 --- a/drivers/clocksource/time-armada-370-xp.c +++ b/drivers/clocksource/time-armada-370-xp.c @@ -246,7 +246,7 @@ static void armada_370_xp_timer_resume(void) writel(timer0_local_ctrl_reg, local_base + TIMER_CTRL_OFF); } -struct syscore_ops armada_370_xp_timer_syscore_ops = { +static struct syscore_ops armada_370_xp_timer_syscore_ops = { .suspend = armada_370_xp_timer_suspend, .resume = armada_370_xp_timer_resume, }; -- 1.9.1
|