Messages in this thread | | | Date | Thu, 28 Jul 2016 21:33:30 +0200 | From | Pavel Machek <> | Subject | Re: v4.1 to v4.7: regression in tsc2005 driver |
| |
Hi!
On Mon 2016-07-25 16:56:20, Pali Rohár wrote: > On Thursday 21 July 2016 08:32:34 Pavel Machek wrote: > > Ok.. so out of the box, touchscreen is "upside down" and miscalibrated > > on n900. So I need to run > > > > xinput --set-prop --type=float 8 115 1.10 0.00 -0.05 0.00 1.18 -0.10 0.00 0.00 1.00 > > xinput --set-prop --type=int 8 249 0 1 > > What these commands do? Or how they change driver behavior?
> As Dmitry wrote, it is possible to move at list "upside down" switch to > kernel/DTS? I think that every N900 touchscreen acts "upside down" by > default...
I don't think that's enough. Its upside down + slightly shifted. If you have time you can try, but...
Pavel -- (english) http://www.livejournal.com/~pavelmachek (cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html
| |