lkml.org 
[lkml]   [2016]   [Mar]   [8]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH 1/5] regulator: pwm: Fix calculation of voltage-to-duty cycle
Date
With following equation for calculating
voltage_to_duty_cycle_percentage
100 - (((req_uV * 100) - (min_uV * 100)) / diff);

we get 0% for max_uV and 100% for min_uV.

Correcting this to
((req_uV * 100) - (min_uV * 100)) / diff;
to get proper duty cycle.

Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Cc: Lee Jones <lee.jones@linaro.org>
---
drivers/regulator/pwm-regulator.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/regulator/pwm-regulator.c b/drivers/regulator/pwm-regulator.c
index 3aca067..4d8eb35 100644
--- a/drivers/regulator/pwm-regulator.c
+++ b/drivers/regulator/pwm-regulator.c
@@ -115,7 +115,7 @@ static int pwm_voltage_to_duty_cycle_percentage(struct regulator_dev *rdev, int
int max_uV = rdev->constraints->max_uV;
int diff = max_uV - min_uV;

- return 100 - (((req_uV * 100) - (min_uV * 100)) / diff);
+ return ((req_uV * 100) - (min_uV * 100)) / diff;
}

static int pwm_regulator_get_voltage(struct regulator_dev *rdev)
--
2.1.4
\
 
 \ /
  Last update: 2016-03-08 13:01    [W:0.068 / U:0.544 seconds]