Messages in this thread | | | Date | Wed, 9 Nov 2016 14:58:28 +0000 | From | Mark Brown <> | Subject | Re: [PATCH V3 1/9] PM / OPP: Reword binding supporting multiple regulators per device |
| |
On Wed, Oct 26, 2016 at 12:02:56PM +0530, Viresh Kumar wrote:
> + Entries for multiple regulators shall be provided in the same field separated > + by angular brackets <>. The OPP binding doesn't provide any provisions to > + relate the values to their power supplies or the order in which the supplies > + need to be configured.
I don't understand how this works. If we have an unordered list of values to set for regulators how will we make sense of them?
> - cpu-supply = <&cpu_supply0>, <&cpu_supply1>, <&cpu_supply2>; > + vcc0-supply = <&cpu_supply0>; > + vcc1-supply = <&cpu_supply1>; > + vcc2-supply = <&cpu_supply2>;
This change doesn't seem to correspond to the documentation change. [unhandled content-type:application/pgp-signature] | |