Messages in this thread | | | From | Benjamin Gaignard <> | Date | Tue, 22 Nov 2016 18:01:11 +0100 | Subject | Re: [PATCH 5/7] add bindings for stm32 IIO timer drivers |
| |
[snip] >> + "st,stm32-iio-timer5" >> + "st,stm32-iio-timer6" >> + "st,stm32-iio-timer7" >> + "st,stm32-iio-timer8" >> + "st,stm32-iio-timer9" >> + "st,stm32-iio-timer10" >> + "st,stm32-iio-timer11" >> + "st,stm32-iio-timer12" >> + "st,stm32-iio-timer13" >> + "st,stm32-iio-timer14" > > We can't do this. This is a binding for a driver, not for the hardware. >
Unfortunately each instance for the hardware IP have little differences like which triggers they could accept or size of the counter register, and I doesn't have value inside the hardware to distinguish them so the only way I found is to use compatible.
| |