Messages in this thread | | | Date | Fri, 29 Jan 2016 16:40:26 +0100 (CET) | From | Jiri Kosina <> | Subject | Re: [PATCH v2] HID: quirks: Add no_init_reports for AKAI midi controller |
| |
On Fri, 29 Jan 2016, Stafford Horne wrote:
> The midi controller times-out while initializing reports, this > causes boot to take an extra 10 seconds. The device descriptor > advertises that it has an internal HID device but seems to not > actually do anything useful. > > Signed-off-by: Stafford Horne <shorne@gmail.com> > --- > Resending the same patch for the keyboard to simply disable init reports, > as discussed with Oliver there might be some hidden functionality which > I will look into. At the moment I dont want to worry about time timeouts. > > Also, I did create and test a patch to use HID_QUIRK_IGNORE which I can > send if you feel strongly about it.
Applied to for-4.5/upstream-fixes.