Messages in this thread | | | From | Pali Rohár <> | Subject | Nokia N900: Adjust MPU OPP values | Date | Sat, 2 Jan 2016 15:31:10 +0100 |
| |
Hello,
MPU OPP table table (omap36xx_vddcore_volt_data) defined in opp3xxx_data.c does not match Nokia N900 phone. For a long time we have dirty patch in linux-n900 tree for it, see:
https://github.com/pali/linux-n900/commit/4644c5801d7469e2be01d847c61df3d934dadd8c
Now when doing transition to device tree, is there any way how correct MPU OOP table for Nokia N900 could be defined in DT file?
-- Pali Rohár pali.rohar@gmail.com [unhandled content-type:application/pgp-signature] | |